Server power management, Server profile operations, Vc profile failover – HP Virtual Connect Enterprise Manager Software User Manual

Page 132

Advertising
background image

Server power management

VCEM might not correctly present the power state of a server when the server is powered off using
VCM.

Server profile operations

To create profiles for Integrity server blades that boot from SAN, you must manually configure
the SAN boot entries in the blade server EFI console.

If the server profile has Flex-10 connections enabled, and server blade NICs (onboard or
mezzanine card) are connected to HP 10/10 Gb-F Virtual Connect Ethernet Module, VC
requires you to power off the server blade to perform any server profile operation.

VC Profile Failover

When you initiate a VC Profile Failover operation, VCEM does not check the compatibility of
the physical connections of the target server. The VC Profile Failover operation automatically
selects an available spare server of the same type and assigns the profile, but assumes that
the correct physical connections are already in place.

When a Failover is executed, HP SIM may not update the servers information. To resolve this
issue, run a manual HP SIM discovery of the affected systems.

Profile operations fail, and the error message "An invalid boot LUN was
entered. Check the storage arrays for the proper LUN number" appears

VCEM requires the boot target LUN configuration and server profiles to be either a 3-digit decimal
between 0-255, or a 16-digit hexadecimal between 0 and FFFFFFFFFFFFFFFF.

This message appears whenever a profile move or failover operation is performed with a server
profile that has a boot LUN that fails to comply with the conditions stated here. This situation can
happen when you create a server profile in VCM, and then try to manage it with VCEM.

To resolve this issue:
1.

Select the VCEM Server Profiles tab.

2.

Select the server profile that is presenting the problem.

3.

Click Edit.

4.

In the boot target configurations table, change all the target LUN fields to be within the allowed
ranges (either a 3-digit decimal between 0-255, or a 16-digit hexadecimal between 0 and
FFFFFFFFFFFFFFFF).

5.

Click OK.

6.

Monitor the job progress until it is complete.

After the operation completes, you can perform move and failover operations on the server profile.

Error popup appears when you select HP predefined ranges during remove
VC Domain from group or delete VC Domain Group operations

Using the web browser in the Japanese language causes an error popup to appear when you
select a HP pre-defined range to be used by a VC Domain that is being removed from a VC Domain
Group.

To resolve the issue:
1.

Clear the Use Pre-defined range check box.

2.

Enter the From and To values for the desired range in the text boxes.

3.

Click OK. Wait until the process completes.

132

Troubleshooting VCEM

Advertising
This manual is related to the following products: