HP XP Racks User Manual

Page 84

Advertising
background image

Description

Error code

(SSB2)

The pair cannot be created because the consistency group number is greater than is allowed.

B990

If this error occurred when you did not specify the consistency group number, Contact HP for assistance.

The Swap Resync operation cannot be performed because the S-VOL is not in PSUS or SSWS status. (Swap
Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL.)

B994

The pair cannot be created because the secondary system path setting is invalid.

B998

The pair cannot be created because Cnt Ac-S Asynchronous is not supported.

B99B

The DKC LDEV configuration might have been changed while starting RAID Manager. Restart RAID Manager.

B9BD

The source of the command device has run out. In LUN Manager, set the command device to OFF, then to
ON.

B9C0

The pair cannot be resynchronized because the pair was not in the Suspend status.

C162

The pair cannot be created because the S-VOL is not available.

C16B

A request for a Pairsplit-S operation was rejected because the status change of the S-VOL failed.

C184

A request for a Pairsplit-S operation was rejected because the pair status was invalid.

C189

A request for a Pairsplit-S operation was rejected because the corresponding volume or group was changing
status.

C18A

The pair cannot be split because the S-VOL pair status was in transition.

C194

A request for a Pairsplit-r operation was rejected because the pair status was already PSUS (by user) PSUS
(because of failure).

C195

Pair split cannot run because the group includes no pair that can be split.

C198

A request for a Pairsplit-r operation was rejected because the corresponding volume or group was changing
status.

C199

The pair's status cannot be changed during the power-on processing of the DKC.

C1BE

The command was rejected because it was issued to a non-Cnt Ac-S volume.

C1D6

The command was rejected because the specified volume is a P-VOL. If the error occurs when the volume
is unpaired, select the volume in Remote Web Console, release the pair using the Yes option for Delete Pair
by Force in the Pairsplit-S dialog box, and then run the command again.

C211

The command was rejected because the specified volume is an S-VOL. If the error occurs when the volume
is unpaired, select the volume in Remote Web Console, release the pair using the Force Delete Pairs window,
and then run the command again.

C212

The command was rejected because the secondary system is not registered, or the registered information
is invalid.

C214

The command was rejected because an internal logical error has occurred.

C215

The command was rejected because the pair status is invalid.

C218

The command was rejected because the P-VOL status is other than PSUS (by user) PSUS (because of failure).

C21A

The command was rejected because the secondary system is not registered, or the registered information
is invalid.

C21C

The command was rejected because the pair release was run on a volume other than P-VOL.

C22A

The command was rejected because the volume is unpaired.

C22C

The command was rejected because the specified volume is the volume other than the P-VOL.

C22D

The command was rejected because the pairsplit command specifying -P option (write protection of P-VOL)
was issued to a volume whose status is not PAIR.

C22E

84

Troubleshooting

Advertising
This manual is related to the following products: