Re-install the service-end lamp housing, Clean the rail encoder strip (bi-weekly) – HP Scitex FB700 Industrial Printer User Manual

Page 72

Advertising
background image

Figure 9-11

Squeeze the sides of the lamp base

Once the lamp housing is installed into the lamp base, tighten the four screws that you loosened
in the previous step.

2.

Install the two screws that secure the lamp housing to the carriage cover (see screws B in

Figure

9-3 User end screws on page 61

for locations).

3.

Connect the auxiliary cable to the top of the lamp. See

Figure 9-1 Disconnect the user-end

auxiliary cable on page 60

for location.

4.

Connect the lamp power cable to the side of the lamp. See

Figure 9-2 Remove the user-end

power cable on page 60

for location.

Re-install the service-end lamp housing

1.

Secure the lamp housing to the lamp assembly using the original two silver screws on the
service end of the carriage (see screws A in

Figure 9-4 Service end screws on page 62

for

locations).

If you have difficultly fitting the lamp housing back onto the lamp base, see “Installing the User-
End Carriage Lamp”

2.

Install the two output-side screws (see screws B in

Figure 9-4 Service end screws on page 62

for locations).

3.

Connect the auxiliary cable to the top of the lamp. See

Figure 9-1 Disconnect the user-end

auxiliary cable on page 60

for location.

4.

Connect the lamp power cable to the side of the lamp. See

Figure 9-2 Remove the user-end

power cable on page 60

for location.

5.

Power up the printer.

Clean the rail encoder strip (bi-weekly)

Ink dust and debris can accumulate on the encoder strip and block accurate reading of the encoder
marks by the carriage encoder reader.

66

Chapter 9 User cleaning

ENWW

Advertising
This manual is related to the following products: