Hardware options installation 57

3.

Remove the drive.

Controller options

The server ships with an embedded Smart Array P420i controller. For more information about the controller

and its features, see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website

(

http://www.hp.com/support/SAC_UG_ProLiantServers_en

). To configure arrays, see the Configuring

Arrays on HP Smart Array Controllers Reference Guide on the HP website
(

http://www.hp.com/support/CASAC_RG_en

).

Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs

on the HP website (

http://www.hp.com/support

).

The server supports FBWC. FBWC consists of a cache module and a capacitor pack. The DDR cache module
buffers and stores data being written by the controller. When the system is powered on, the capacitor pack

charges fully in about 5 minutes. In the event of a system power failure, a fully charged capacitor pack

provides power for up to 80 seconds. During that interval, the controller transfers the cached data from DDR

memory to flash memory, where the data remains indefinitely or until a controller retrieves the data.

CAUTION:

The cache module connector does not use the industry-standard DDR3 mini-DIMMs.

Do not use the controller with cache modules designed for other controller models, because the

controller can malfunction and you can lose data. Also, do not transfer this cache module to an

unsupported controller model, because you can lose data.

CAUTION:

To prevent a server malfunction or damage to the equipment, do not add or remove

the battery pack while an array capacity expansion, RAID level migration, or stripe size migration

is in progress.

CAUTION:

After the server is powered down, wait 15 seconds and then check the amber LED

before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do

not remove the cable from the cache module. The cache module is backing up data, and data is
lost if the cable is detached.

IMPORTANT:

The battery pack might have a low charge when installed. In this case, a POST

error message is displayed when the server is powered up, indicating that the battery pack is

temporarily disabled. No action is necessary on your part. The internal circuitry automatically

recharges the batteries and enables the battery pack. This process might take up to four hours.

During this time, the cache module functions properly, but without the performance advantage of
the battery pack.