HP XP Continuous Access Software User Manual

Page 110

Advertising
background image

110

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

Level 4 is the default setting and must not be changed
unless directed by an HP service representative.

Setting a trace level to other than 4 can impact problem
resolution if a program failure occurs.

Levels 0 to 3 are for troubleshooting.

When a change option to the trace control parameter is
specified, a warning message is displayed, and the
command enters interactive mode.

–b m

Sets a trace level.

y

specifies buffered mode.

n

specifies synchronous mode.

–q

Terminates interactive mode and exits this command.

–s

size(KB)

Changes the default trace buffer size, which is 1 MB, in
units of 1,024 bytes.

–t

type

Sets a trace type to the one specified in type. When a
type is specified, only traces of the specified type are
output. A value between 0 and 511 can be specified.
Two or more values can be specified.

–z

(Not for use with MPE/iX)

This option makes this

command enter interactive mode.

–zx

(Not for use with MPE/iX or OpenVMS)

This option

prevents using RM in interactive mode.

–S

Shuts down RM.

–D

Displays the RM command device name currently used
by RM.

If the command device is blocked due to the online
maintenance (microprogram replacement) of the disk

Advertising
This manual is related to the following products: