HP XP Continuous Access Software User Manual

Page 176

Advertising
background image

176

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

If the specified raw_device is listed in multiple device
groups, this applies to the first one encountered.

–d

[g] seq# LDEV# [ MU# ]

Searches the RM instance configuration file (local
instance) for a volume that matches the specified
sequence # and LDEV. If a volume is found, the
command is executed on the paired logical volume

(–d) or group (–dg).

This option is effective without specification of the
–g group

option.

If the specified LDEV is listed in multiple device
groups, this applies to the first one encountered.

seq # LDEV #

can be specified in hexadecimal (by the

addition of 0x) or decimal format.

–E

(BC only) Issued to forcibly suspend a paired volume
(for example, when a failure occurs). It is not normally
used.

–FCA

[MU#]

Used to forcibly specify a cascading CA volume in a
combination CA and BC environment. If the –l option
is specified, this option splits a cascading CA volume
on a local host (near site). If no –l option is specified,
then this option splits a cascading CA volume on a
remote host (far site).

The target CA volume must be a P-VOL, or the

–R[S][B

] option can be specified on the S-VOL.

The MU# specifies the cascading mirror descriptor for
CA-Journal.

–FBC

[MU#]

Used to forcibly specify a cascading BC volume in a
combination BC and CA environment. If the –l option
is specified, this option splits a cascading BC volume
on a local host (near site). If no –l option is specified,

Advertising