252

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

–v cflag

Displays all flags for checking regarding data block
validation for target volumes.

Example

# raidvchkscan -p CL1-A -v cflag

PORT# /ALPA/C TID# LU# Seq# Num LDEV# BR-W-E-E MR-W-B BR-W-B SR-W-B-S

CL1-A / ef/ 0 0 0 2332 1 0 D E B R D D D D E E D E D D

CL1-A / ef/ 0 0 1 2332 1 1 D E B R D D D D E E D E D D

CL1-A / ef/ 0 0 2 2332 1 2 D E B R D D D D E E D E D D

CL1-A / ef/ 0 0 3 2332 1 3 D E B R D D D D E E D E D D

CL1-A / ef/ 0 0 4 2332 1 4 D E B R D D D D E E D E D D

BR-W-E-E

displays the flags for checking data block

size.

R=Read

→ E=Enable and D=Disable

W=Write

→ E=Enable and D=Disable

E=Endian format

→ L=Little and B=Big

E=Not rejected when validation error

→ W=Write

and R=Read


MR-W-B

displays the flags for checking block header

information.

R=Read

→ E=Enable and D=Disable

W=Write

→ E=Enable and D=Disable

B=Block #0

→ E=Enable and D=Disable


BR-W-B

displays the flags for checking data block

number information.

R=Read

→ E=Enable and D=Disable

W=Write

→ E=Enable and D=Disable

B=Data Block

→ E=Enable and D=Disable


SR-W-B-S

displays the flags for checking data block

checksum.

R=Read

→ E=Enable and D=Disable

W=Write

→ E=Enable and D=Disable

B=Block #0

→ E=Enable and D=Disable

S=Checksum

→ E=Enable and D=Disable

Advertising