Troubleshooting RAID Manager

275

EX_ENPERM

A device mentioned in the
configuration file does not have
permission for a pair operation.

Use the pairdisplay or raidscan –find
verify

command to confirm that a pair

operation is permitted for the device.

EX_ENQCTG

The CT group in a group does not
match the CTGID number.

Confirm the CTGID by using the
pairvolchk

command.

EX_ENQSER

The group that was designated by
paircreate

(for BC) does not have the

same disk array unit, or the unitID is
not identical to the unitID of the same
serial# of the disk array.

Confirm the serial# by using the
pairdisplay

or the raidqry –r command.

EX_ENQSIZ

Unmatched pairing volume size.

Use the raidscan -f command to confirm
the volume size or number of the LUSE
volume, and change the SIZE of the
volumes to match.

EX_ENQVOL

The attributes or the fence level of the
primary and secondary volumes do not
match.

Confirm the attributes and fence level
settings using the pairdisplay command
and reset the volume attributes and fence
levels.

EX_ENXCTG

An available CT group for an Open
Systems volume does not exist for
asynchronous CA or BC.

Confirm whether all CT groups are
already used by other volumes.

EX_EPRORT

Mode changes denied due to retention
time

Verify the retention time for a target
volume using the raidvchkscan -v gflag
command.

EX_ERANGE

The argument or the result of the
argument exceeds the maximum
command value.

Re-issue the command, making sure to
correctly define all of the command
arguments.

EX_ERPERM

RAID permission denied.

Use the inqraid -CLI and raidqry -h
commands to confirm the type of RAID
permitted for RM.

(continued)

Command Error Problem

Action