HP XP Continuous Access Software User Manual

Page 254

Advertising
background image

254

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

Available(Bsize)

: This displays the available capacity

for the volume data on the SnapShot pool in units of
Bsize.

Capacity(Bsize)

: This displays the total capacity in the

SnapShot pool in units of Bsize.

[Note] This command will be rejected with
EX_ERPERM by connectivity checking between Raid
Manager and Array.

-v pid [unit#]

(XP12000 only) Displays SnapShot pool

information

Example

# raidvchkscan -v pid 0

PID POLS U(%) SSCNT Available(MB) Capacity(MB) Seq# Nnm LDEV#

001 POLN 10 330 10000000 1000000000 62500 2 265

002 POLF 95 9900 100000 1000000000 62500 3 270

003 POLS 100 10000 100 1000000000 62500 1 275

004 POLN 0 0 1000000000 1000000000 62500 2 280

005 POLE 0 0 0 0 62500 0 0

PID

: Displays the SnapShot pool ID.

POLS

: Displays the following status in the SnapShot

pool.

- POLN

: Pool Normal.

- POLF

: Pool Full.

- POLS

: Pool Suspend.

- POLE:

Pool Failure; when in this state, pool

infomation will not be displayed.

U(%):

Displays the usage rate of the SnapShot pool.

SSCNT

: Displays the number of SnapShot volumes in

SnapShot pool.

Available(MB)

: Displays the available capacity for the

volume data on the SnapShot pool.

Advertising