Table 11, Led functions 102 – HP StorageWorks 2300 Disk System User Manual

Page 102

Advertising
background image

102

Troubleshooting

LED states are described in Table 11:

Table 11.

LED Functions

LED

State

Indication

System Power

Green

Power is on

OFF

Power is off

System Fault

Amber

Self-test

1

/ Problem

2

OFF

Normal operation

Flashing

BCC A & B DIP switch settings
do not match.

BCC Fault

Amber

Self-test

1

/ Fault

OFF

Normal operation

Flashing

Peer BCC DIP switch settings
do not match or BCC not installed properly

Term. Pwr.

Green

Termination power is available
from the host.

Flashing

Activity on the bus

OFF

There is no termination power.

Full Bus

Green

Disks are on a single bus of 14
addresses.

OFF

Disks are split between two buses,
seven addresses each

1 Start-up and self-tests occur briefly when the unit is

powered on.

2 A component has failed; temperature or voltage is out of

normal range. See Isolating Faults on page 104

3 When a disk is installed with power on, its activity LED

blinks on momentarily indicating a SCSI bus reset. When
the disk is ready, the LED blinks once and turns off.
Thereafter, it flashes when there is I/O to the disk.

Advertising