HP Hitachi Dynamic Link Manager Software User Manual

Page 59

Advertising
background image

2. HDLM Functions

37

#1

When you turn the intermittent error monitoring function off, information about

paths not subject to automatic failback will be reset. If you do not want to reset

the information about paths not subject to automatic failback when you turn the

intermittent error monitoring function off, change the target paths to

Offline(C)

.

#2

The number of errors and the time passed since error monitoring had started are

both reset to

0

, and then monitoring restarts from the time the setting change is

made in accordance with the changed monitoring conditions.

#3

The number of errors and the time passed since error monitoring had started are

both reset to

0

, and then monitoring restarts from the time the HDLM manager

starts.