GENERAL INSTALLATION INSTRUCTIONS

Ensure gas supply and gas type, as shown on unit nameplate agree.

Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1-1996, the National Gas

Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable

and in accordance with local codes.

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the

unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if

necessary to move unit.

Pipe threading compound must be resistant to the action of liquefied petroleum gases.

DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and

water solution before operating unit.

Noncombustible clearances:

0" sides (0 mm)

0" rear (0 mm)

Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the

flue.

Adequate clearance for air openings into the combustion chamber is required. Do not place objects

between the bottom of the unit and the counter top.

There must be adequate clearance for removal of the front panel. All major parts except the burners are

removable thru the front if the gas line is disconnected.

“THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED

INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND

SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE

GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING

REGULATIONS / I

REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE

FOLLOWING BRITISH STANDARD CODES OF PRACTICE - BS 6172, BS 5440 PART 2, BS 6891"

"THISAPPLIANCE MUST BE INSTALLED INACCORDANCE WITH THE RULES IN FORCE”

"MUST BE INSTALLED INAWELLVENTILATEDAREA. Ventilation requirements ie. B.S. 5440.”

We strongly recommend having a competent professional install this equipment. Such a person should be

familiar with local gas regulations. A gas company representative should approve the completed

installation.

Caution:

CANADIAN INSTALLATION MUST COMPLY WITH THE CANADIAN ELECTRICAL CODE, CSA C22.2

ASAPPLICABLE.

European Community Installation Instructions:

IMPORTANT:

THESE UNITSARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.

EE.

!

!

NOTICE: Local codes regarding installation vary greatly from one area to another. The National

Fire Protection Association, Inc. states in its NFPA96 latest edition that local codes are “Authority

Having Jurisdiction” when it comes to requirement for installation of equipment. Therefore,

installation should comply with all local codes.