2-15

2.6 ZEROING PROCEDURES (Continued)

7. Fire a 3-round shot group and note the center of the shot

group relative to the designated strike point. Re-tighten

the rail grabber bracket.

8. Rotate the Aim Laser adjusters to move the center of the

shot group to the designated strike point.

9. Fire another 3-round shot group and again observe the

center of the new shot group relative to the designated

strike point.

10. When 5 out of 6 consecutive rounds are in the

designated strike zone, the ATPIAL / weapon

combination is zeroed.

11. Once the aiming beams are zeroed, rotate the Mode

Selector to the DL (DUAL LOW) or DH (DUAL HIGH)

position to observe both the IR aiming and illumination

beams. Rotate the Illuminator adjusters to center the

illumination beam over the IR aiming beam.

Advertising