All custom events have the following 7 fields:

These fields are populated differently for each query command. The text length (String Encode) field is
not used in any command.

Custom Event Fields

Field

Description

Uint Flag

0 means text is a standard string, 1 means Unicode encoded string

slong value1

button state number

slong value2

actual length of string (this is not encoded size)

slong value3

index of first character (usually 1 or same as optional index

string text

the text from the button

text length (string encode)

button text length

Button Query Commands

?BCB

Get the current
border color.

Syntax:

"'?BCB-<vt addr range>,<button states range>'"

Variable:

variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

1 = Off state and 2 = On state).
custom event type 1011:
Flag - zero
Value1 - Button state number
Value2 - Actual length of string (should be 9)
Value3 - Zero
Text - Hex encoded color value (ex: #000000FF)
Text length - Color name length (should be 9)

Example:

SEND COMMAND Panel,"'?BCB-529,1'"

Gets the button 'OFF state' border color. information.
The result sent to the Master would be:
ButtonGet Id = 529 Type = 1011
Flag = 0
VALUE1 = 1
VALUE2 = 9
VALUE3 = 0
TEXT = #222222FF
TEXT LENGTH = 9