Monitoring the stack, Visually monitoring the stack, Monitoring the stack -36 – Alcatel-Lucent OMNISWITCH 6800 User Manual

Page 116: Visually monitoring the stack -36

Advertising
background image

Monitoring the Stack

Managing OmniSwitch 6800 Series Stacks

page 3-36

OmniSwitch 6800 Series Hardware Users Guide

June 2007

Monitoring the Stack

As shown in the previous sections, monitoring the current status and operation of all elements in a stack
can help users avoid unexpected stack conditions. The table below includes CLI commands that are useful
in monitoring stack conditions.

Visually Monitoring the Stack

Users can also monitor many stack operations by viewing the front panel LEDs on all elements in the
stack. Refer to

“Status LEDs” on page 2-13

for detailed information on LEDs and stack status.

CLI Commands Used for Monitoring a Stack

show stack topology

Displays the current operating topology of switches within a stack.

show stack status

Displays the current redundant stacking cable status and token
availability for a stacked configuration.

show running-directory

Displays the directory from where the switch was booted. This com-
mand also shows important information, including whether the soft-
ware across the stack is synchronized.

show chassis

Displays basic configuration and status information for the switch
chassis.

show cmm

Displays basic hardware and status information for primary and
secondary management modules operating in the stack.

show ni

Displays basic hardware and status information for modules currently
operating in the stack.

show module

Displays basic information for modules installed in the stack. Modules
include primary and secondary management modules and any modules
operating in idle status.

show module long

Displays detailed information for modules installed in the stack. Mod-
ules include primary and secondary management modules and any
modules operating in idle status.

show module status

Displays basic status information for modules installed in the stack.
Modules include primary and secondary management modules and any
modules operating in idle status.

show power

Displays hardware information and current status for chassis power
supplies. This includes the status of backup power supplies, if applica-
ble.

show fan

Displays the current operating status of each of the six fans operating in
each chassis.

show temperature

Displays the current operating chassis ambient temperature, as well as
current temperature threshold settings for each of the modules in the
stack.

Advertising