OmniSwitch 6800 Series Chassis and Hardware Components

Power Cords

OmniSwitch 6800 Series Hardware Users Guide

June 2007

page 2-27

Note.

Chapter 3, “Managing OmniSwitch 6800 Series Stacks,”

provides important information on virtual

chassis behavior during and after a boot. Consulting this chapter is strongly recommended for users oper-
ating switches in a stacked configuration.

Power Cords

Because the power cord is the switch’s only disconnect device, it should be plugged into an easily
accessible outlet. In the event that your power cord is lost or damaged, refer to the specifications below.

Specifications

The power cord to be used with 115-Volt configuration is a minimum type SJT (SVT) 18/3, rated at 250
Volts AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug
and the other end terminates in a NEMA 5-15P plug.

The power cord to be used with 230-Volt configuration is minimum type SJT (SVT) 18/3, rated 250 Volts
AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug and
the other end terminates as required by the country where it will be installed.

European cords must be Harmonized (HAR) type. Refer to the information below for power plug types by
region:

Power Cord Types

North America

NEMA 5-15-P (US), C22.2, No. 42 (Canada)

United Kingdom / Ireland

BS 1,363

Europe

CEE 7/7

Japan

JIS 8,303

Australia

AS 3,112

India

BS 546

Italy

CIE 2,316

Switzerland / Liechtenstein

SEV 1011

Denmark / Greenland

SRAF 1,962 / D816 / 87

Argentina

AR1-10P