Control Port Operation

HDSL2 for General Distribution Installation and Maintenance Practice

26

61223HDSL2L2-5B

Total Access 3000 H2TU-C Auto In Service Status Screen
The Auto In Service Status Scr

een

(

Figure 23

) provides the status of the Auto In Service

feature.
The T1 alarm indications will display if the External Alarms option is enabled on the Provi-
sioning menu (

Figure 17

).

The Auto In Service Status screen also indicates the startup or exit period remaining as either
1, 4, 8, or 24 hours. This is the time during which the unit monitors both loop synchroni-
zation (Loop Sync) and T1 alarms (if enabled) and will only go into (or out of) service if the
circuit remains synchronized and without T1 alarms during the entire measured period.
These times are also set from the Provisioning menu. System responses displayed in the
status fields on this screen are shown in

Table 11

below.

A single menu option is provided to view the Alarm History Screen. This screen is also
available by selecting the HDSL2 Main Menu option.

Figure 23. Auto In Service Screen

Table 11. Auto In Service Status Indications

Status Field Name

System Indications

Current Auto In Service State (line 1)

In-Service
Out-of-Service Maintenance

Auto In Service Status (line 2)

Currently in startup period
Currently in exiting period
OK, Startup Period COMPLETED
OK, Startup INCOMPLETE (forced in-service)

Auto In Service Criteria (line 3)

DSL Loop Sync (T1 alarms ignored)
DSL Loop Sync and absence of T1 alarms

Criteria (current status)

DSL Loop Sync = OK or LOS (LOS shown in

Figure 23

)

T1 Alarm Status = Alarm or OK

Shelf: 1 Slot: 15 Total Access System 03/01/05 09:29
Unacknowledged Alarms: None
Circuit ID:
Auto In Service Status Screen

Current Auto In Service State = Out-of-Service Maintenance
Auto In Service Status = Currently in Startup Period
Auto In Service Criteria = DSL Loop Sync (T1 alarms ignored)

NOTE: The external alarms provisioning option determines
whether T1 alarms are an auto in service criterion.
Enabling external alarms sets T1 alarms as a criterion.

Criteria Status
--------------- ------
DSL Loop Sync LOS

---Startup Period Timer---
4 hrs 0 mins
--------------------------------------------------------------------------------