Table 14, H2tu-r troubleshooting guidelines – ADTRAN HDSL2 User Manual

Page 64

Advertising
background image

Troubleshooting

HDSL2 for General Distribution Installation and Maintenance Practice

54

61223HDSL2L2-5B

Table 14

provides an H2TU-R troubleshooting guide to assist in problem resolution.

Table 14. H2TU-R Troubleshooting Guidelines

Condition

Solution

All front panel indicators are
off.

1. Make sure the H2TU-R is properly seated in the housing.
2. Check powering voltage:

• For Span Powered unit (1223026L2) verify that the H2TU-C is

delivering sufficient simplex voltage to the loop.

• For Local Powered unit (1223024L2) verify that –48 VDC is

properly connected.

3. If steps

1

and

2

pass, replace the H2TU-R.

Power is present and ade-
quate, but loop sync is not
available (

DSL

LED is off).

1. Verify that the loop conforms with CSA guidelines (not too long,

etc.). For more information, refer to

“HDSL2 Deployment Guide-

lines”

.

2. Verify that loop loss at 196 kHz is not greater than 35 dB.
3. Verify that noise on the HDSL2 loop is within acceptable limits.
4. If steps

1

through

3

pass and loop sync is still not available,

replace unit.