Figure 31, Performance data definitions, loop, Figure 32 – ADTRAN HDSL2 User Manual

Page 42: Performance data definitions, path, Screens

Advertising
background image

Control Port Operation

HDSL2 for General Distribution Installation and Maintenance Practice

32

61223HDSL2L2-5B

Figure 31. Performance Data Definitions, Loop

Figure 32. Performance Data Definitions, Path

Circuit ID:HNTSVLALHDSL2 03/01/05 09:29:45
Press ESC to return to previous menu

Performance Data Definitions

H2TUC, H2TUR, and H2R LOOP Related: HDSL2 Framing
ES-L Errored Seconds CRC>=1 or LOSW>=1
SES-L Severely Errored Seconds CRC>=50 or LOSW>=1
UAS-L Unavailable Seconds >10 cont. SES-Ls

DS1 and DSX-1 Line Related: Superframe and Extended Superframe
ES-L Errored Seconds (BPV+EXZ)>=1 or LOS>= 1
SES-L Severely Errored Seconds (BPV+EXZ)>=1544 or LOS>=1
UAS-L Unavailable Seconds >10 cont. SES-Ls
PDVS-L Pulse Density Violation Secs EXZ>=1; >7 zeros if B8ZS, >15 if AMI
B8ZS-L B8ZS Seconds B8ZS coded signal received
CV-L Code Violation Count (BPV+EXZ) count

NOTE: Reverse video indicates invalid data due to a terminal restart (or power
cycle), a data register reset, or a system date or time change.

N. Next
P. Previous Selection:

Circuit ID:HNTSVLALHDSL2 03/01/05 09:29:45
Press ESC to return to previous menu

Performance Data Definitions

DS1 and DSX-1 Path Related: Superframe Extended Superframe
ES-P Errored Seconds FE>=1 or CRC>=1 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
SES-P Severely Errored Seconds FE>=8 or CRC>=320 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
UAS-P Unavailable Seconds >10 cont. SES-Ps >10 cont. SES-Ps
SAS-P SEF/AIS Seconds SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
ES-PFE Far End Errored Seconds n/a PRM bits G1-G6,SE,
or SL=1, or RAI
CV-P Code Violation Count FE count CRC error count

NOTE: Under a UAS-P condition, ES-P and SES-P counts are inhibited.
Under a SES-L or SES-P condition, the respective CV-L or CV-P count is
inhibited.

P. Previous Selection: