Troubleshooting, Table 13, H2tu-c troubleshooting guidelines – ADTRAN HDSL2 User Manual

Page 63

Advertising
background image

HDSL2 for General Distribution Installation and Maintenance Practice

Troubleshooting

61223HDSL2L2-5B

53

TROUBLESHOOTING

Table 13

provides a H2TU-C troubleshooting guide to assist in problem resolution.

Table 13. H2TU-C Troubleshooting Guidelines

Condition

Solution

All front panel indicators are
off.

1. Verify that –48 VDC power is properly connected to the shelf.
2. Inspect the fuse and verify that it is not blown.
3. Insert the H2TU-C into a slot known to be in good working condi-

tion, and check the LED indicators.

4. If steps

1

and

2

pass, but step

3

fails, replace the H2TU-C.

DSL

LED is solid Red.

Loop has poor signal quality or loss of sync. Basic troubleshooting
procedures should identify a problem with the cable pair.

DSX/DS1

LED is solid Red.

Errors are being taken on the DSX-1, DS1 or HDSL2 loop. The craft
interface will identify the source. BERT tests toward the appropriate
loopbacks should also reveal the source of the problem.

ALM

LED is solid Red.

Loss of DSX-1 signal to the unit.

ALM

LED is Yellow.

If customer equipment is not installed, initiate an H2TU-R to Network
Loopback and perform a BERT test. If this test fails, or the craft inter-
face indicates a loss of sync, then there is a potential problem with
the cable pair that should be identified through basic troubleshooting
procedures.

Advertising