Chapter 3: Programming

Installation and Maintenance Manual

12

3.14: Power-Up in a Position or RPM

The 1995B can power up displaying either Position or RPM data.

The power-up mode is programmed by entering the following:

A)

Unit must be in the “Program” mode.

B)

Depress

. If a zero (0) is entered,

ENT

CIR# - 1 - 6

3

-

-

(0 or 1)

-

ENT

-

positional data will be displayed upon power-up; if a one (1) is entered, the unit will power up

displaying RPM.

3.15: Decimal Point Programming

A continuous, nonfloating decimal point may be programmed on the display. If a scale factor is selected

that needs a decimal point in order to properly display its resolution in engineering units, the following 50

series codes are used:

50 - No decimal point;

clears existing decimal point

123

51 - Tenths

12.3

52 - Hundreths

1.23

To program a decimal point, enter the following:

A)

Unit must be in the “Program” mode.

B)

Depress

.

Example:

CIR# 50

=

123

CIR# 51

=

12.3

CIR# 52

=

1.23

ENT

CIR# - 50 or 51

52

or

-