Chapter 1: introduction/description, Programmable features 1.2: general information – AMETEK 1995B Micro-Set PLS with Brake Monitor User Manual

Page 5

Advertising
background image

1

Installation and Maintenance Manual

Chapter 1: Introduction/Description

Scale Factor

There is one scale factor only, permanently set to 360.

Electronic Offset

Fully programmable offset to any number with the scale factor.

Motion Detector

LS5 can be programmed for either limit switch or motion detect

output.

Expansion Outputs

Programmable to accommodate up to 29 circuits.

See Section 1.2: General Information - Software Option “P” for more options.

Chapter 1: Introduction/Description

The 1995B Micro-Set is a fully self-contained, single-turn resolver-based programmable limit switch.

It includes a three-digit LED display, five output relays, and one fault check relay, and it is fully pro-

grammable for the following features:

1.1: Programmable Features

1.2: General Information

The 1995B Micro-Set is a fully self-contained, microcomputer-based Programmable Limit Switch

(PLS) with a convenient keypad for programming each independent output circuit to open or close at

the desired settings. This system allows precise position control of rotary motion.

A 1995B consists of a resolver-based transducer, resolver-to-programmer cable assembly, and the

programmer, which provides five limit switch outputs, one fault check output and one brake monitor

output. The optional output expansion modules will add six additional limit switch outputs per module,

and up to four expansion modules can be driven by the programmer, for a total of twenty-nine limit

switch outputs.

The single-turn resolver transducer generates a ratiometric analog signal representing an absolute rotary

position. This ratiometric signal is converted to a digital signal at the Micro-Set. A microprocessor

calculates and/or converts these signals based on user-programmed data.

As the transducer passes through the preprogrammed dwell settings, the programmer outputs can

energize solenoids, relays, or solid-state circuitry to control external circuits.

The 1995B PLS was designed for use in rotary and/or rotary-to-linear applications. It incorporates

many features for safe, efficient operation.

The completely self-contained unit can operate up to 29 independent outputs (five standard) based on

the rotary position of the resolver.