Chapter 7: Remote Circular Display

Installation and Maintenance Manual

24

Chapter 7: Remote Circular Display

NOTE: When using a remote circular display, the maximum number of outputs is limited to 23 outputs

or three expansion boards.

The Remote Circular Display (1995-1446) is ideal for mechanical stamping presses and shears.

Either position or RPM can be displayed on the large 3/4” LED digital display. A 360° bar graph will

increment in 10° intervals showing the angle of the resolver.

The remote circular display gets its RS422 synchronous signal from the four-place terminal strip located

on the back of the 1995 programmer. The display can be located up to 1,000 feet away from the

programmer. See Fig 11-3, Chapter 11: Wiring Diagrams.

Installation and wiring of the remote circular display should be followed in the same manner as the

1995B described earlier in Chapter 2: Installation.

7.1: POS/RPM On Remote Circular Display

The 3/4” LED display can display either position or RPM while the bar graph will always show angular

position. To display RPM install a jumper wire from Pin 6 (RPM) to Pin 7 (GND) on the 11-place

connector located on the bottom of the remote circular display.