Chapter 4: Expansion Modules

Installation and Maintenance Manual

14

Chapter 4: Expansion Modules

The 1995L PLS provides six outputs. A 1995E Expansion Module is required for each additional six

outputs desired, up to a total of 30 outputs, or four expansion modules. The circuit location of each

expansion module is defined by the location of a two-pin jumper on an eight-pin block in the upper left

corner of the module. This jumper must be installed for the expansion module to operate. Two pairs of

pins, located in the lower right corner of the expansion module, should be jumpered on only the last

module in the wiring group. See Fig. 10-4 (Chapter 10: Wiring Diagrams) for additional expansion

module wiring information. Each expansion module is provided with a full set of terminal strip designa-

tion decals. To avoid confusion, the appropriate decals should be installed along the output terminals,

based on the location of the output selection jumper outlined below.

Fig. 4-1

See Section 3.5: Selecting Number of Outputs, for instructions on how to program unit for use with

expansion modules.