Chapter 8: Specifications

Installation and Maintenance Manual

20

Chapter 8: Specifications

8.1: 1995 Micro-Set PLS Programmer

8.2: Mechanical Relay

(Single Pole, Double Throw)

Resolution

-12 Bit (4096)

Scale Factor

-2 to 1,000

Temperature

-32°F to 125°F (Operating)

Range

-0°F to 150°F (Storage)

Operating Voltage

-110/120V AC 50/60 Hz 300 mA

INPUTS

Transducer

-Analog LDT o to 10 Volt output

***4 -20mA available as special

Logic

-Fault check and security 5V DC at 10mA. May be operated

by isolated contact, current sourcing or current sinking device.

OUTPUTS

-Plug-in relays listed below

Contact Relay

-10 Amp Isolated Contact

Pick-Up

-2 ms

Drop-Out

-15 ms

8.3: AC Solid-State

(Single Pole, Normally Open)

Maximum Load

-1 Amp

Load Voltage Range

-70 - 250V AC Zero Voltage Switching

Leading Current

-3 mA at 120V AC

Voltage Drop w/Output On

-3.0V RMS or Less

Inputs

-N.O. and Common

Operate & Reset Time

-1/2 cycle of line voltage max. +1ms or less