17

Installation and Maintenance Manual

Chapter 6: Security Inputs

Chapter 6: Security Inputs

The Run/Program security inputs may be operated by an isolated contact, current sourcing, or a current

sinking device, 5V DC @ 10mA. See Fig. 10-1, Fig. 10-2 OR Fig. 10-3 (Chapter 10: Wiring Dia-

grams) for wiring options.

NOTE: The 1995 PLS cannot be programmed until the security input has been actuated - continuity

- between +5V DC and “Security +” input and between “Security -” input and ground.

NOTE: If the Run/Security program is not needed (always in the Program mode) install jumper wires

form Pin 9 (+5V DC) to Pin 10 (Security +) and from Pin 11 (Security -) to Pin 14 (GND)

on the 16-place LDT connector.