3 Programming the DVC Family

DVC710 Program Loader Monitor

he "Programming Tool" is used to create your application for the DVC710. The "Program Loader Monitor" is

) Architect your system. In the design process compile a total list of digital inputs, pulse inputs, PWM outputs

a wide variety of

Intella Programming Tool or from the File menu select New or press CNTL + N, then from the File

DVC710 and expansion module’s

nction (i.e. Sequence of Operations) refer to Appendix F for additional

files into the DVC710.

T
used to load the user application into the DVC710 module and monitor the inputs and outputs in real-time as
your application executes. Both programs are located in the Windows Start Menu under the c:\Program
Files\HCT Products. In order to create a user application, the following steps generally should be followed:

a

etc. A total I/O count is needed to assure the correct amount of DVC inputs / outputs are specified in
external modules, if needed. Also, remember to allow room for expansion with spare I/O.

b) Define your system components and their interactions. HCT does have experience with

sensor manufactures. Request a sensor recommendation sheet of sensors known to work with the HCT
system.

c) Start the

Menu, select Save As and name your project, i.e. hydraulic log splitter.

d) Add any planned expansion modules displays etc and configure the

inputs and outputs that drive or sense your components. With the mouse on the screen, right click to
choose the expansion module. Insert the expansion module, set the modules unique name and Mac ID#.
Assign names to the real world I/O.

e) Create a flow diagram of machine fu

information. Once the Sequence of Operations (SoO) is complete, this needs to be converted into a
program. The ‘always’ code as well as bubble logic sequences will be used during this step. Refer to
section 5 for programming examples. Refer to Appendix A for compiler keywords. Program the control
logic as to how the outputs respond to the inputs.

f) Compile the program.
g) Load the compiled program
h) Run your system and debug your application.

P/N: 021-00163, Rev. A.0 - for V5.2 Tools