Digital Inputs

Name Description

Range

Name

Set/Get the state of the switch

False or Off, True or On

Name.RealRPM

The Unsigned Integer Value of the RPM.
For Pulse inputs Only

0 to 9999

Name.PulseTimeout

Get/Set Pulse Timeout for Loss of Signal

0 to 65535

Name.PulsesPerRev

Get/Set Pulses Per Revolution

0 to 9999

Name.Counter

Get/Set Unsigned Integer Value of the
Counter. Pulse inputs Only

0 to 65535

Name.LOS

Loss of Signal flag set after time out. For
Pulse inputs Only

False (Pulses ok), True (No Pulse
Input)


High Side Only

Name Description

Range

HSEvenName

Set the Bang-bang Coil to On or Off

Off, On

HSEven#Name.OpenDisable Set the Disable Coil Open Detection

0 [Enabled], 1 [Disabled]

HSEven#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil Short]

HSEven#Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil Open]

HSOddName

Set the Bang-bang Coil to On or Off

Off, On

HSOdd#Name.OpenDisable

Set the Disable Coil Open Detection

0 [Enabled], 1 [Disabled]