High Country Tek emc-3L User Manual

Page 45

Advertising
background image

Single Coil High Side

Name Description

Range

(Low-Side/PWM) Name

Set the state Current Target or Process
in percentage of min to max current 0 = 0
Current, .1% = Min Current, and 100% =
Max Current

0% to 100%

Name.Enable

Set the PWM to 0 or enable the PWM

True [PWM Enabled], False [PWM =
0]

Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil Short]

Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil Open]

Name.Rampup

Set the ramp up rate (time to travel from
0% to 100%)

0.0 to 65.00 s

Name.Rampdown

Set the ramp down rate (time to travel
from 100% to 0%)

0.0 to 65.00 s

HSEvenName

Set the Bang-bang Coil to On or Off

Off, On

HSEven#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil Short]

HSEven#Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil Open]

HSOdd#Name.OpenDisable Set the Disable Coil Open Detection

0 [Enabled], 1 [Disabled]

HSOdd#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil Short]

HSOdd#Name.Open

Get/Set the Coil Flag for Open Status

Off [Coil Ok], On [Coil Open]

Name.Cur

Current actual * CurGain = amps

0 – 3.5 amps

Name.RampCur

Current ramped Currend*CurGain= amps 0 – 3.5 amps

Name.CurErr

Current Error = RampCur – Cur

16 Signed Integer

Name.CurSumErr

Current Error accumulated over time

0 – 65535

Name.CurP

Current Proportional Term Constant “P”

0 – 255

Name.CurI

Current Proportional Term Constant “I”

0 – 255

Name.MinCurA

Minimum Current Coil A *.001 = amps

0 – 3.5 amps

Name.MaxCurA

Maximum Current Coil A *.001 = amps

0 – 3.5 amps

Name.Config

Configuration Word –Output, Process,
Coil

0 = DCHS, 1 = SCHS, 3 = SCLS

P/N: 021-00163, Rev. A.0 - for V5.2 Tools

Page | 45

Advertising
This manual is related to the following products: