background image

Process PI Variables

Name Description

Range

Name.Set-point

The desired % set point position for the
output

0 to 100%

Name.Feedback

The % feedback position for the output

0 to 100%

Name.ProErr

Error = Set point – Feedback

16 bit signed integer

Name.ProSumErr

Error accumulated over time

0 – 65535

Name.ProP

Process Proportional Term Constant “P”

0 – 255

Name.ProI

Process Proportional Term Constant “I”

0 – 255

Name.ProItime

Update / Integration Time

0.0 to 650.00 s

Name.Cur

Current actual * CurGain = amps

0 – 3.5 amps

Name.RampCur

Current ramped Currend*CurGain= amps 0 – 3.5 amps

Name.CurErr

Current Error = RampCur – Cur

16 bit signed integer

Name.CurSumErr

Current Error accumulated over time

0 – 65535

Name.CurP

Current Proportional Term Constant “P”

0 – 255

Name.CurI

Current Proportional Term Constant “I”

0 – 255

Name.MinCurA

Minimum Current Coil A *.001 = amps

0 – 3.5 amps

Name.MaxCurA

Maximum Current Coil A *.001 = amps

0 – 3.5 amps

Name.MinCurB

Minimum Current Coil B *.001 = amps

0 – 3.5 amps

Name.MaxCurB

Maximum Current Coil B *.001 = amps

0 – 3.5 amps

Name.Config

Configuration Word – Output, Process,
Coil

P/N: 021-00163, Rev. A.0 - for V5.2 Tools