Burr King BK75 User Manual

Page 18

Advertising
background image

Cabinet Dust Collector, Series 50 to 80

17

6. Mount the gauge and bracket assembly to the

supporting structure using two self-drilling
screws.

7. Thirty-five feet of plastic tubing is supplied and

must be cut in two sections. Connect one
section of tubing from the gauge’s high-pressure
port to the pressure fitting located in the dirty-
air chamber. Connect remaining tubing from
the gauge’s low-pressure port to the fitting in
the clean-air chamber. Additional tubing can be
ordered from your representative.

8. Carefully remove the cloth protecting the

filters. Close access doors and tighten securely
by hand.

9. Zero and maintain the gauge as directed in the

manufacturer’s Operating and Maintenance
Instructions provided.

Magnehelic Gauge Detail A


50 10.14
60 13.14
70 12.02
80 14.08

4.75

4.00

.406 diameter

2 places

Series

Advertising