Burr King BK75 User Manual

Page 24

Advertising
background image

Cabinet Dust Collector, Series 50 to 80

23

Chamber Silencer

1. Place the chamber silencer over the clean-air

outlet on top of the unit.

2. Position silencer flush with the front of the unit

and the exhaust opening facing the front.

3. Secure with all four latches.

Chamber Silencer

Automatic Shaker

The automatic shaker is driven by a 1/10 Hp
TENV gear motor controlled by a solid-state timer.
The timer control box can be ordered with or
without step-down transformers. A timer control
box without the transformer requires a 120-Volt
AC power supply controlled by a customer-supplied
fan starter. Input power is supplied to the timer on
fan motor shutdown, through the normally-closed
auxiliary contact of the fan starter. After a 60-
second delay, the timer energizes and the shaker
motor starts for a 30-second fixed time. Turning the
unit ON and OFF initiates the shaker sequence.
Wiring
1. Mount the timer control box in a convenient,

accessible location on or near the unit.

2. Complete the wiring to the fan starter, timer,

and shaker motor according to the appropriate
wiring diagram.

Automatic Shaker Installation

latch

Front

shaker bar

shaker motor

relay

bracket clip

capacitor

red wire

blue wire

yellow/black wire

shaker motor

motor mount

shaker motor

cover

shaker motor

shaker bar

1/2 x 5/8-in

coupling

10-24 x 1 1/2-in

truss head screw

bearing bracket

assembly

10-24 hex nut

#10 lock

washer

shaker bar

Advertising