Aalborg XFM Digital User Manual

Page 8

Advertising
background image

5

Figure b-1 - XFM 15 PIN "D" CONNECTOR CONFIGURATION

IMPORTANT NOTES:

Generally, "D" Connector numbering patterns are standardized. There are, how-
ever, some connectors with nonconforming patterns and the numbering sequence
on your mating connector may or may not coincide with the numbering sequence
shown in our pin configuration table above. It is imperative that you match the
appropriate wires in accordance with the correct sequence regardless of the par-
ticular numbers displayed on the mating connector.

Make sure power is OFF when connecting or disconnecting any cables in
the system.

The (+) and (-) power inputs are each protected by a 300mA M (medium time-lag)
resettable fuse. If a shorting condition or polarity reversal occurs, the fuse will cut
power to the flow transducer circuit. Disconnect the power to the unit, remove the
faulty condition, and reconnect the power. The fuse will reset once the faulty con-
dition has been removed. DC Power cable length may not exceed 9.5 feet (3
meters). Use of the XFM flow transducer in a manner other than that specified in
this manual or in writing from Aalborg, may impair the protection provided by the
equipment.

ƽ

ƽ

PIN XFM

FUNCTION

1

Common, Signal Ground For Pin 2
(4-20 mA return)

2

0-5 Vdc or 4-20mA Flow Signal Output

3

Relay No. 2 - Normally Open Contact

4

Relay No. 2 - Common Contact

5

Common, Power Supply
(- DC power for 11 to 26 Vdc)

6

Relay No. 1 - Common Contact

7

Plus Power Supply
(+ DC power for 11 to 26 Vdc)

8

RS485 (-) (Optional RS232 TX)

9

RS232 Signal GND (RS-485 GND Optional)

10

Do not connect (Test/Maintenance terminal)

11

Relay No. 2 - Normally Closed Contact

12

Relay No. 1 - Normally Open Contact

13

Relay No. 1 - Normally Closed Contact

14

Do not connect (Test/Maintenance terminal)

15

RS485 (+) (Optional RS232 RX)

Shield Chassis Ground