AL200 ALERT2 Encoder, Modulator, and Sensor Interface

3. Under

Device Type, select AL200.

4. Click the browse button next to

Communication Port and select the port

associated with the AL200.

5. Click

OK.

6. Click

Connect.

7. Specify the settings on each tab as described below.

Main

Set the

Operation Mode to ALERT2 on CS I/O, ALERT

Concentration on RS-232.

ComPort

Leave all settings as defaults.

ALERT2

Configure settings to match your ALERT2 network.

Radio Settings

Default settings will work for Campbell Scientific’s RF320 series

radios. (Campbell Scientific’s RF320 series uses the Ritron DTX-L

series.) For other radios, check with the manufacturer for necessary

radio settings.

GPS Settings

Leave all settings as defaults.

Sensor Input Settings

Leave all settings as defaults.

5. Overview

The AL200 ALERT2 Encoder, Modulator, and Sensor Interface is designed for

use in radio networks using the ALERT2 protocol. The AL200 can be

configured to operate as a stand-alone device or as a datalogger peripheral. In

stand-alone mode, the AL200 will measure sensors, perform calculations, and

if appropriate, transmit the data during a designated time slot. In datalogger

peripheral mode, the AL200 will receive data from a datalogger, such as the

CR800 or CR1000, or other device and transmit this data during a designated

time slot. In both modes, the AL200 will receive ALERT data on one of the

serial ports, then concentrate and retransmit the data via the ALERT2 protocol.