Appendix b. cables and connector pin descriptions, B.1 cs i/o, B.2 rs-232 – Campbell Scientific AL200 ALERT2 Encoder, Modulator, and Sensor Interface User Manual

Page 25

Advertising
background image

Appendix B. Cables and Connector Pin

Descriptions

B.1 CS I/O

CS I/O is an interface unique to Campbell Scientific products. CS I/O uses

TTL signaling. CS I/O devices are connected using a 9-pin, straight-through,

male to female cable with all 9 pins connected. Use of the supplied SC12 cable

(pn 16675) is recommended.

TABLE B-1. CS I/O Pin Description

Pin Datalogger Function, DB9 Female AL200 Function, DB9 Male
1

5 VDC

N/C

2

SIGNAL GND

SIGNAL GND

3

RING

RING

4

RXD

TXD

5

ME

ME

6

SDE

SDE

7

CLK/HS

CLK/HS

8

12 VDC

N/C

9

TXD

RXD

B.2 RS-232

RS-232 is used for asynchronous serial communication. It is a standard

EIA/TIA-232 DB9 socket female DCE interface. A DB9 male to male null

modem cable (pn 18663) is used to connect the AL200 to a Campbell

Scientific datalogger’s RS-232 port.

TABLE B-2. RS-232 Pin Description

Pin AL200 Function, DCE, DB9 Female
1

N/C

2

TXD

3

RXD

4

N/C

5

SIGNAL GND

6

N/C

7

CTS

8

RTS

9

N/C

B-1