Campbell Scientific AL200 ALERT2 Encoder, Modulator, and Sensor Interface User Manual

Page 34

Advertising
background image

Appendix D. AL200 Settings

SE1 Transmitted

Last three transmitted readings for SE1 (T0, T1, T2). The list will be queried and

displayed here at a regular refresh interval. While connected via Device

Configuration Utility, automated reporting/transmission is disabled. Press and hold

the test button for 3 to 5 seconds to force a transmission while connected.

C1 Raw Reading

If C1 input is enabled, this will be either a) the control port state or b) the value for

SDI-12 without

SDI-12 Multiplier and SDI-12 Offset applied, during the last sensor

scan. While connected via Device Configuration Utility, C1 will be measured every

Configuration Sensor Scan Interval. The measured value will be queried and

displayed here at a regular refresh interval.

C1 Scaled Reading

If C1 input is enabled, this will be either a) the control port state or b) the value for

SDI-12 with

SDI-12 Multiplier and SDI-12 Offset applied, during the last sensor

scan. While connected via Device Configuration Utility, C1 will be measured every

Configuration Sensor Scan Interval. The measured value will be queried and

displayed here at a regular refresh interval.

C1 Transmitted

If C1 input is enabled, this will be either a) the control port state or b) the value for

SDI-12 for the last three transmitted readings of C1 (T0, T1, T2). The list will be

queried and displayed here at a regular refresh interval. While connected via Device

Configuration Utility, automated reporting/transmission is disabled. Press and hold

the test button for 3 to 5 seconds to force a transmission while connected.

D-4