Appendix A. Edlog Program Examples

A.1 CR10X Pulse Count Example Program

The CR10X program will also work with the CR500, CR510, CR10, 21X or
CR23X. CR7 programming is similar to the CR10X but has an additional
parameter in the Pulse (P3) instruction to specify the slot that the pulse card is
in.

;{CR10X}
*Table 1 Program
01: 1.0000

Execution

Interval

(seconds)


1: Pulse (P3)
1: 1

Reps

2: 1

Pulse

Channel

1

3: 2

Switch Closure, All Counts

4: 3

Loc [ Rain_mm ]

5: 0.254

Multiplier

6: 0

Offset


2: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


3: Set Active Storage Area (P80)
1: 1

Final Storage Area 1

2: 101

Array

ID


4: Real Time (P77)
1: 1220

Year,Day,Hour/Minute (midnight = 2400)


5: Totalize (P72)
1: 1

Reps

2: 3

Loc [ Rain_mm ]


*Table 2 Program
01: 0

Execution

Interval

(seconds)


*Table 3 Subroutines

End Program

A-1