Appendix A. Edlog Program Examples

A-2

A.2 CR10X Control Port Example

This example measures a TE525 rain gage in millimeters. A different
multiplier would be entered (TABLE 7-3) for other units.

;{CR10X}
;
*Table 1 Program
01: 1

Execution

Interval

(seconds)


1: Pulse (P3)
1: 1

Reps

2: 8

Control Port 8 (switch closure only) ;Black wire connect to C8

3: 2

Switch Closure, All Counts

4: 1

Loc [ Rain_mm ]

5: .254

Multiplier

6: 0

Offset


2: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)


3: Set Active Storage Area (P80)
1: 1

Final Storage Area 1

2: 101

Array

ID


4: Real Time (P77)
1: 1220

Year,Day,Hour/Minute (midnight = 2400)


5: Totalize (P72)
1: 1

Reps

2: 1

Loc [ Rain_mm ]


*Table 2 Program
02: 0.0000

Execution

Interval

(seconds)


*Table 3 Subroutines

End Program

Output Instruction 72, Totalize, is used in the output section of the program to
output the total rainfall over the output interval. This section should be
executed every scan and not placed in a subroutine or conditional statement.