4 goesstatus read error register – Campbell Scientific TX312 High Data Rate GOES Transmitter User Manual

Page 25

Advertising
background image

TX312 Transmitter

TABLE 5.1-3. GoesStatus Command 2: Read Last Message Status

Index Contents

1

Command Result Code

2

Message type: Self-timed or Random

3

Size of message in bytes

4

Forward power in tenths of watts

5

Reflected power in tenths of watts

6

Power supply voltage under full load, in tenths of volts

7

GPS acquisition time in tens of seconds

8

Oscillator drift (signed, hundreds of Hz)

9 Latitude

degrees

10 Latitude

minutes

11 Latitude

seconds

12 Longitude

degrees

13 Longitude

minutes

14 Longitude

seconds.

5.1.2.4 GoesStatus Read Error Register

Example:

Public Errors(10)

GoesStatus(Errors(), 4)

Command 4 (Read Error Register) is used to return the total number of errors
that have occurred, and codes describing the last four errors. When the
command that caused the error is listed as 31, the error is an internal fault.
Otherwise the error is just a communication error.

TABLE 5.1-4. GoesStatus Command 4: Read TX312 Error Registers

Index Contents

1 Result

Code

2

Number of Errors

3

Command that Caused the Error

4 Error

Code

5

Command that Caused the Error

6 Error

Code

7

Command that Caused the Error

8 Error

Code

9

Command that Caused the Error

10 Error

Code

19

Advertising