Appendix D. RAWS-7 Data Format

D-15

95: Do (P86)
1: 10

Set Output Flag High (Flag 0)


; Set resolution high
96: Resolution (P78)
1: 1

High

Resolution


; Write row 10 to final storage
97: Sample (P70)
1: 3

Reps

2: 22

Loc [ SRad_Old ]


; set resolution low
98: Resolution (P78)
1: 0

Low

Resolution


; Copy row 10 to transmitter
99: Data Transfer to HDR GOES (P126)
1: 0

Self-Timed/Append

2: 8

ASCII

xxxxx

Format

3: 14

Result Code Loc [ P126_RC ]


100: Do (P86)
1: 10

Set Output Flag High (Flag 0)


; Write row 11 to final storage
101: Sample (P70)
1: 3

Reps

2: 25

Loc [ FM_Old ]


; Copy row 11 to transmitter
102: Data Transfer to HDR GOES (P126)
1: 0

Self-Timed/Append

2: 7

ASCII

xxx

Format

3: 14

Result Code Loc [ P126_RC ]


103: End (P95)

*Table 2 Program
02: 600

Execution Interval (seconds)


1: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 180

Interval (same units as above)

3: 30

Then

Do


2: HDR GOES Status (P127)
1: 2

Read Last Message Status

2: 30

Result Code Loc [ L_Msg_RC ]