2 speak text command – Campbell Scientific VSP3 Vosponder Voice Radio Interface User Manual

Page 16

Advertising
background image

Section 2. Programming the Datalogger

2-4

2.2 Speak Text Command

The speak text command can be used for alarming conditions. Example 2-4 is
a program that shows how the speak text command could be formatted.

Example 2-4. Program to send text string to the Vosponder

*Table 1 Program

01: 10

Execution Interval(seconds)

1: Batt Voltage (P10)

1:

1

Loc [ BatVolts ]

;IF BATTERY VOLTAGE IS LESS THAN 10.5 VOLTS…
1: If (X<=>F) (P89)

1:

1

X Loc [BatVolts ]

2:

4

<

3:

10.5

F

4:

30

Then Do

;EVERY FIVE MINUTES
2: If time is (P92)

1:

0

Minutes (Seconds --) into a

2:

5

Interval (same units as above)

3:

30

Then Do

;INITIATE AN ALARM MESSAGE OVER THE RADIO LINK
11: SDI-12 Recorder (P105)

1:

1

SDI-12 Address

2:

0

Start Measurement (aM0!)

3:

1

Port

;Control Port C1

4:

1

Loc [ BatVolts ]

;Starting location, but ignored

5:

1.0

Mult

;in “Speak Text” mode

6:

0.0

Offset

12: Extended Parameters 4 Digit (P68)

1:

88

Option

;Send “X” to indicate an extended command

2:

84

Option

;Send “T”, Speak Text Command

3:

32

Option

;Send a Space Character

4:

83

Option

;Send “S”

5:

73

Option

;Send “I”

6:

84

Option

;Send “T”

7:

69

Option

;Send “E”

8:

32

Option

;Send a Space Character

13: Extended Parameters 4 Digit (P68)

1:

51

Option

;Send “3”

2:

49

Option

;Send “1”

3:

32

Option

;Send a Space Character

4:

76

Option

;Send “L”

5:

79

Option

;Send “o”

6:

87

Option

;Send “w”

7:

32

Option

;Send a Space Character

8:

66

Option

;Send “B”

Advertising