Section 5. Testing and Troubleshooting

5.1 ERROR Codes

When in the terminal mode, error codes may be directed to the screen to aid in
troubleshooting. The following table provides context for the error codes.

TABLE 5-1. Terminal Error Codes

Error Code

Cause

Corrective Action

2

Attempt to use transparent
command in slave mode

Change to master mode

3

SDI-12 transparent mode
timed out

Re-enter transparent mode

4

Logger data overrun

Reduce the number of data
values or the number of
characters in the data values to
102 or less.

6

N-V memory ID error

Use correct SDI-12 address

7

N-V memory load error

Retry image upload

5.2 Frequently Asked Questions

Problem:

I should be hearing voice messages on my radio handset, but
I’m not.

Solution:

Check the following:

1.

Check the radio handset

a. Wait a minute and try again. Sometimes the Vosponder

can be busy and doesn’t pick up the code on the first try.
It also takes about two program execution intervals
before the datalogger fully runs the program.

b. If you have a second handset, can you talk to the other

handset? If not, you may need to change the handset’s
batteries or recharge them. If this doesn’t correct the
problem, then you may need to have the handset
repaired or replaced.

c. Make sure that the handset is set to the same frequency

and channel as the radio that is located at the remote
site.

d. Make sure the volume on the handset is not turned down

so low that you can’t hear any voice transmission.

e. Make sure the squelch on the handset is not turned up so

high that you can’t hear transmissions.

Advertising