8: If (X<=>F) (P89)

1: 3

X Loc [ ws_diag ]

2: 2

<>

3: 0

F

4: 19

Set Intermed. Proc. Disable Flag High (Flag 9)

9: Wind Vector (P69)

1: 1

Reps

2: 0

Samples

per

Sub-Interval

3: 0

S, theta(1), sigma(theta(1)) with polar sensor

4: 2

Wind Speed/East Loc [ wnd_spd ]

5: 1

Wind Direction/North Loc [ wnd_dir ]


10: Totalize (P72)
1: 1

Reps

2: 4

Loc [ samples ]


11: If (X<=>F) (P89)
1: 3

X Loc [ ws_diag ]

2: 1

=

3: 1

F

4: 29

Set Intermed. Proc. Disable Flag Low (Flag 9)


;Report the total of diag = 1.
;
12: Totalize (P72)
1: 1

Reps

2: 4

Loc [ samples ]


13: If (X<=>F) (P89)
1: 3

X Loc [ ws_diag ]

2: 1

=

3: 2

F

4: 29

Set Intermed. Proc. Disable Flag Low (Flag 9)


;Report the total of diag = 2.
;
14: Totalize (P72)
1: 1

Reps

2: 4

Loc [ samples ]


15: If (X<=>F) (P89)
1: 3

X Loc [ ws_diag ]

2: 1

=

3: 4

F

4: 29

Set Intermed. Proc. Disable Flag Low (Flag 9)


;Report the total of diag = 4.
;
16: Totalize (P72)
1: 1

Reps

2: 4

Loc [ samples ]