Campbell Scientific WINDSONIC 2-D Sonic Wind Sensors User Manual
Page 26
WindSonic Two-Dimensional Sonic Anemometer
8: If (X<=>F) (P89)
1: 3
X Loc [ ws_diag ]
2: 2
<>
3: 0
F
4: 19
Set Intermed. Proc. Disable Flag High (Flag 9)
9: Wind Vector (P69)
1: 1
Reps
2: 0
Samples
per
Sub-Interval
3: 0
S, theta(1), sigma(theta(1)) with polar sensor
4: 2
Wind Speed/East Loc [ wnd_spd ]
5: 1
Wind Direction/North Loc [ wnd_dir ]
10: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
11: If (X<=>F) (P89)
1: 3
X Loc [ ws_diag ]
2: 1
=
3: 1
F
4: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
;Report the total of diag = 1.
;
12: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
13: If (X<=>F) (P89)
1: 3
X Loc [ ws_diag ]
2: 1
=
3: 2
F
4: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
;Report the total of diag = 2.
;
14: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
15: If (X<=>F) (P89)
1: 3
X Loc [ ws_diag ]
2: 1
=
3: 4
F
4: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
;Report the total of diag = 4.
;
16: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
18