Campbell Scientific WINDSONIC 2-D Sonic Wind Sensors User Manual
Page 27
WindSonic Two-Dimensional Sonic Anemometer
17: If (X<=>F) (P89)
1: 3
X Loc [ ws_diag ]
2: 1
=
3: 8
F
4: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
;Report the total of diag = 8.
;
18: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
19: If (X<=>F) (P89)
1: 3
X Loc [ ws_diag ]
2: 1
=
3: 9
F
4: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
;Report the total of diag = 9.
;
20: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
21: If (X<=>F) (P89)
1: 3
X Loc [ ws_diag ]
2: 1
=
3: 10
F
4: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
;Report the total of diag = 10.
;
22: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
23: If (X<=>F) (P89)
1: 1
X Loc [ wnd_dir ]
2: 4
<
3: -99990 F
4: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
;Report the total of samples of no wind.
;
24: Totalize (P72)
1: 1
Reps
2: 4
Loc [ samples ]
25: Do (P86)
1: 29
Set Intermed. Proc. Disable Flag Low (Flag 9)
*Table 2 Program
01: 0.0000 Execution
Interval
(seconds)
19