FRONT PANEL AOJUSTMENTS

Touch Key

1 Index: Allows the following adjustments to be selected.

1) Set point temperature

O-14OO'F (760°C)

O-2500°F (O-137O°C)

2) Heat cycle time

3) Prop. Band (indicated

*1 to 120 seconds

as gain)

0.25-25% of span

4) Rate with tracking reset

**4-255 seconds

5) Auto Tune (AT)

Up/Down keys: increases/decreases values of above

adjustments.

Tune/Cancel: "cancel" puts output on stand-by to

permit set-up

"tune" triggers automatic tuning procedure

E Enter: writes selected value to nonvolatile memory

NOTES: *setting to zero initiates 60 millisecond timebase

for ultra fast cycling. Use with external solid

state relays or SCR Power Controllers.

**Setting to zero disables reset and rate action

for proportional only control. Reset is six times

higher than rate

FOR OPTIMUM RESULTS WITH THE AUTO-TUNE MODEL 6050

1. Set point must be a minimum of 100°F above ambient for

proper start-up.

2. Multi-zone applications require auto-tune units on each

zone and simultaneous warm-up.