Appendix B — Using the document feeder option

50

3.

Grasp both free corners of the jammed sheet and pull it out slowly.

4.

Close the cover of the transportation module.

Maintaining the document feeder option

Cleaning the guide flap

The guide flap on the underside of the ADF keeps documents at the correct scanning position and
guides them into the output tray after scanning. To prevent printing ink and other contaminants from
accumulating on the flap and interfering with image quality, wipe it periodically with an ink-free cloth
or cotton swab moistened with industrial alcohol.

Roller cleaning

Prolonged use of the ADF may result in accumulation of ink and other contaminants on the feeder's
input roller, reducing the roller's efficiency. Check for dirt on the roller if the ADF starts to have
trouble pulling paper through properly. The input roller should be cleaned periodically using a lint-
fee cloth or swab moistened with ethylene chloride.

Note: Do not attempt to turn the roller while cleaning it; this may damage the ADF's drive

mechanism.