Installing the Bridging Converter

20

Planning the Installation

Be sure to observe the following guidelines when planning the installation of
your bridging converter.

The fiber optic port on the bridging converter must be connected to a
companion bridging converter (i.e., AT-FS238a/1 to AT-FS238b/1 or
AT-FS238b/1 to AT-FS238b/2), or to a fiber optic port that is IEEE
802.3ah-compliant and whose operating specifications are compatible
with the fiber optic port on the converter.

The end-node connected to the 10Base-T/100Base-TX twisted pair
port can operate at either 10 Mbps or 100 Mbps.

The twisted pair cabling must be kept away from sources of electrical
noise, such as radios, transmitters, power lines, broadband amplifiers,
electrical motor, and fluorescent fixtures.

Table 3 lists the cabling specifications for the twisted pair port.

Table 3 10Base-T/100Base-TX Twisted Pair Cabling Specifications

Operating Mode

Cable Type

Maximum Operating
Distance

10Base-T

Shielded or unshielded Category 3 or better

100 m (328 ft)

100Base-TX

Shielded or unshielded Category 5 or better

100 m (328 ft)