Maintenance

E. Component Replacement

When component replacement involves breaking a gas pipe connection, check the
new connection with soap solution or an appropriate leak detector. DO NOT USE A
FLAME TO TEST FOR LEAKS.

Internal wiring is marked as shown on the circuit schematic drawings (inside
control housing and in this manual). Be sure that new components are wired in the
same manner as old components. An examination of the circuit schematic shows
that the safety components are wired in series. In most cases, a faulty component
may be isolated with a jumper wire to verify that the component is faulty. If this
determination is made, contact a certified Service Agency for assistance.