Troubleshooting – Blodgett 40GS-KLS Series User Manual

Page 20

Advertising
background image

18

OM-40GS-KLS

Troubleshooting

Your kettle will operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event
of a problem. If the actions suggested do not solve the problem, call your qualified Service Representative. If an item on the list is
followed by a X , the work should be done by a qualified service representative.

USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER AND/OR AUTHORIZED
DISTRIBUTOR CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.

CAUTION

USING REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY AN THEIR AUTHORIZED

DISTRIBUTOR CAN CAUSE OPERATOR INJURY AND EQUIPMENT DAMAGE AND WILL VOID ALL WARRANTIES.

SYMPTOM

WHO

WHAT TO CHECK

X indicates items which must be performed by an authorized technician.

Kettle continues heating
after it reaches the desired
temperature.

User

a. Thermostat dial setting.

Auth Service

Rep Only

b. Thermostat calibration.
c. Thermostat operation. The thermostat should click when the
dial is rotated above and below the setting for the
temperature of the kettle. X

Kettle stops heating before
it reaches the desired
temperature.

User

a. Thermostat dial setting.

Auth Service

Rep Only

b. Thermostat calibration. X
c. Thermostat operation. Thermostat should click when the
dial is rotated above and below the setting for the
temperature of the kettle. X

Pressure relief valve pops
open.

User

a. For air in the jacket. See “Jacket Vacuum” in the Maintenance section.
b. Thermostat dial setting.

Auth Service

Rep Only

c. For defective thermostat. The thermostat should click when the dial
is rotated to settings above and below the temperature of the kettle. If
defective, replace. X
d. For defective safety valve. If the valve pops at pressures below 29
PSI, replace. X

Burners will not light.

User

a. That the main gas supply valve is open. (handle is in line with the gas
pipe).
b. Gas supply to the building.

Auth Service

Rep Only

c. Thermostat operation. The thermostat should click when the dial is
rotated to settings above and below the temperature of the kettle. X

System does not produce
a spark.

Auth Service

Rep Only

a. AC voltage between terminals on secondary side of transformer with
unit power turned on. If it is not 24 Volt, replace the transformer. X
b. That the high tension cable is firmly attached and in good condition. If
cracked or brittle, replace. X
c. Pilot burner ceramic insulator for crack or break. X
d. Pilot spark gap. Regap. X