Timer – Spektrum SPM3100 DX3R User Manual

Page 21

Advertising
background image

21

SPEKTRUM DX3R PROGRAMMING GUIDE

TIMer

User Name

01: Model 01

Timer

Internal Reset

Int 0:08:19

Int 0:08:18

Timer A:

Dn Tmr 05:00

Timer B:

The DX3R offers three types of timers:

Internal timer:

Automatically records the time that the transmitter is

turned on. Timer A is defaulted to the internal timer.

Up timer:

The Up Timer is triggered via a selectable button/

switch and counts up from 00:00 seconds,

functioning as a stopwatch. It is useful for timing a

fuel run to determine fuel mileage/ pit stop strategy

or, for electrics, to time the run time of a pack to

determine gear ratio and setup information. To pause

the Up timer, press the button/switch that the timer

is programmed to. To reset the UP timer to 00:00,

press and hold the programmed button for more

than 3 seconds.

Down timer:

Can be programmed for up to 99 minutes and 99

seconds in one-second increments. Normally this

timer is programmed for the length of the race

with electrics and is defaulted to 5:00 minutes, or

the duration of the fuel tank in gas, warning the

driver that it’s time to pit and refuel. The Down

timer is started via a selectable programmable

switch. When the down timer expires, an alarm

will sound and the timer will begin to count up.

To pause the Down timer, press the button/switch

that the timer is programmed to. To reset the Down

timer to its preprogrammed value, press and hold

the programmed button for more than 3 seconds.

Timer B is defaulted to the Down timer, the time is

defaulted to 5:00 minutes and button F is defaulted

to actuate the down timer.
Two of the three timers can be selected and

displayed on the main screen. The user name and

model number and model name are also displayed

in this screen.

To aCCess The TIMer funCTIon:

From the List screen rotate the roller to highlight the

Timer function.
Press the roller to enter the Timer function. The

Timer screen will be displayed as shown above.
Rotate the roller to highlight the desired Timer that

you choose to program (Timer A or Timer B).
Press the roller to enter the highlighted Timer

function.
Rotate the roller to select:
Int- Internal

Dn Tmr- Down Timer

Up Tmr- Up Timer

Note: If Down timer is selected, pressing the

roller again will allow the time to be changed

by rotating the roller.

To reset the internal timer, rotate the roller to

highlight Internal Reset then press the roller to reset

the internal timer to 0:00:00.
See System on page 28 for details on programming

the timers to various buttons and switches.

Advertising